"On the replacement of water as coupling medium in scanning acoustic microscopy analysis of sensitive electronics components."
Predictive Image together with CNES conducted a study on the replacement of water as coupling medium in scanning acoustic microscopy analysis of sensitive electronics components
/public/media/files/HertlEtAl_MicroelectronicsReliability-2020.pdf
General presentation was done by M. Hertl during digital ESREF conference in Oct. 2020.